INSTALLATION

CHOICE OF MATERIAL FOR INSTALLATION

The material can be panels/brick with an insulation value
greater than 0.03 m² x K/W.
The insulation is defined as wall thickness (in metres) divided
by the wall's Lambda value.
Contact your installation technician/chimney inspector.
During testing, the fireplace insert is installed in a cabinet
made from non-flammable 50 mm calcium silicate panels
(Skamotec 225).
The fireplace insert must be installed in heat-resistant material.
See the following pages for the installation dimensions and
the installation distances for 600-1, 600-2 and 600-3.
GB - 11