English
RAIS - Manual for RAIS Poleo II, RAIS Epoca II
Installation distance in case of combustible wall
To find out whether the wall next to where the stove is going to be installed is flammable,
you should contact your building contractor or the local building authorities.
The hearth should be able to accommodate the weight of the stove. The chimney must
be independently supported by wall brackets or a ceiling support plate. The weight of the
stove is indicated in the brochure.
The stove should always be installed on a non-combustible hearth of a size and construc-
tion that is in accordance with the provisions of the current UK Building Regulations Ap-
proved Document
J.
If the stove is to be installed on a wooden floor, it must be covered with a non-combusti-
ble material at least 12 mm thick, in accordance with UK Building Regulations Approved
Document J, to at distance of 300 mm in front of the stove and 150 mm to each side
measuring from the door of the combustion chamber.
The clearance distances to combustible material beneath, surrounding or upon the hearth
and walls adjacent to the hearth should comply with the guidance on the separation of
combustible material given in UK Building Regulations Approved Document J and also in
these stove instructions.
37