Attaching The Needle; Checking The Needle - JUKI TL-2200QVP Mini Manuel D'instructions

Masquer les pouces Voir aussi pour TL-2200QVP Mini:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Adjusting the thread tension
CAUTION:
Figure as observed from the front
Flat face
Flat face of
needle
22
Turn OFF the power switch when replacing the needle.
Tightens
Loosens
Needle clamp screw
Flat face
Parallel
Flat plate

■ Attaching the needle

1. Turn off power.
2. Lower the presser foot.
3. Move the needle bar up to the highest position of its
stroke.
4. With the flat face of the new needle facing to the
right, insert the new needle into the needle bar until
it can go no further. Then tighten the needle clamp
screw.
* The needle to be used is HAx1.

■ Checking the needle

Check the needle for its straightness occasionally. Any
defective needle would cause needle breakage, stitch
skipping, thread breakage or damage to materials.

Publicité

Table des Matières
loading