1.1 SPECIFICATIONS
TABLE 1
ITEM
NATURAL GAS (NG)
INPUT: Hi
19,000 Btu/hr (5.57 kW)
INPUT: Lo
13,500 Btu/hr (3.96 kW)
MANIFOLD PRESSURE: Hi
3.5" w.c. (0.87 kPa)
COLLECTEUR DE PRESSION: FORT
HI-LO BURN FLO SET SCREW
# 50
SALUT-LO GRAVER FLUX VIS
Minimum: 5.0" w.c. (1.2 kPa)
GAS INLET SUPPLY PRESSURE:
Maximum: 13.5" w.c. (3.4 kPa)
ENTREE DE PRESSION
ORIFICE SIZE: @ 0-4500'
# 45 DMS
FORMAT D'ORIFICE:
AIR SHUTTER
OPEN 1/8"min
VOLET DE L'AIR
(3.175mm)
CONTROL VALVE TYPE:
TYPE DE SOUPAPE
Skytech AF-40004
Existing 5" B-Vent venting intake air
VENTING
ÉVACUATION
2-ply aluminum flexpipe exhaust
FAN
Variable Speed (115 Volt)
VENTILATEUR
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING
PLATE.
CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUÉ SUR LA
PLAQUE SIGNALÉTIQUE.
WARNING
This fireplace will only operate when the fan is on. (see page 29)
Ce foyer ne fonctionne que lorsque le ventilateur est en marche. (voir page 29)