Direct Vent Information / Direct Vent D'information - Sierra Flame BRADLEY-NG Manuel D'installation Et Guide De L'utilisateur

19,000 btu gaz naturel
Table des Matières

Publicité

3.3.3 DIRECT VENT INFORMATION / DIRECT VENT D'INFORMATION

Use existing 5''certified B-vent pipe from B-vent fireplace being removed as the air intake for this
installation. Install 3'' (76.2mm) x 2 ply certified flex-pipe aluminum venting down middle of existing
5'' (127mm) certified B-vent pipe.
Minimum Height (3'' (76.2mm) & 5'' (127mm) pipe) 11 feet (132''/3352.8mm) from top of fireplace unit
Maximum Height (3'' (76.2mm) & 5'' (127mm) pipe) 50 feet (600''/15240mm) from top of fireplace unit
Maximum Offset - 6 feet (72''/1828.8mm) at 45° angle
Minimum Straight Pipe 15'' (381mm) from top of fireplace to center of first elbow
This fireplace is for replacement of B-Vent units only using existing 5"certified B-
Venting and must terminate through the roof. No side venting allowable.
5" certified flexpipe and certified B-vent adaptor (ECCO part # 5DHC) can be used to
join from the existing 5" pipe to the top of the fireplace. If flexpipe is used then existing
Ce foyer est pour le remplacement des unités B-Vent utilisant seulement 5 existante "certifié
B-ventilation et doit se terminer par le toit. Aucune ventilation latérale admissible. 5 «certifié
Flexpipe et certifié adaptateur évent de type B (ECCO partie # 5DHC) peuvent être utilisés pour
joindre de l'actuel 5" tuyau vers le haut de la cheminée. Si Flexpipe est utilisé existant alors 5
"évacuation nécessitera cerclage à l'appui.
5" venting will require strapping to support.
Page 20 of 45

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lc773211

Table des Matières