Tunze Comline DOC Skimmer 9006 Mode D'emploi page 75

Table des Matières

Publicité

Failure: The foam formation decreases after a
certain period of time.
Cause: The internal silicone air hose is pinched or
kinked.
Remedy: Place the hose without kinks, and
replace it, if and when necessary. Check all air
conducting parts (nipples, caps) for free passage
and tightness, and replace them, if and when
necessary. Check that the hose is not pressed
between the hydrofoamer and skimmer body.
Cause: The Hydrofoamer is not operational or
operates with interruptions.
Remedy: Remove the Hydrofoamer; take off
the impeller housing, and check the play of
the impeller. Clean the impeller, if and when
necessary. Replace defective impeller or any
defective parts. In case of invisible defects:
Allow a workshop to check the motor block and
replace it, if and when necessary.
Disfonctionnement
produite diminue après une certaine période.
Raison : Le tuyau d'air interne en silicone est plié.
Solution : Disposez sans plis le tuyau d'air en
silicone, remplacez si nécessaire. A cette
occasion, vérifiez toutes les pièces du circuit
d'air (raccords, obturateurs) en ce qui concerne
leur libre passage ou leur étanchéité, remplacez
si nécessaire. Vérifiez si le tuyau silicone
n'est pas pincé entre le corps de l'écumeur et
l'Hydrofoamer.
Raison : L'Hydrofoamer ne fonctionne pas ou par
intermittence.
Solution : Démontez l'Hydrofoamer, déposez le
corps de pompe et vérifiez les jeux au niveau de
la turbine. Nettoyez les pièces défectueuses ou
remplacez si nécessaire. Pour des défauts non
visibles, faites vérifier le bloc-moteur en usine ou
remplacez si nécessaire.
:
La
quantité
d'écume
75

Publicité

Table des Matières
loading

Table des Matières