The use of outside combustion air is mandatory on this pellet stove.
The outside air connection pipe protrudes from the lower rear center of the
stove; use the included outside air kit to attach your stove to outside
combustion air. Instructions and all the parts needed to make the outside air
connection to your pellet stove are included with the outside air kit.
If it is not feasible to use the included outside air hookup kit in your stove
installation, other materials may be used, provided the following rules are
followed:
The pipe used for outside air hookup must be metal, with a minimum
thickness of .0209 in. (25 gauge mild steel) or greater and an inside
diameter of approximately 2.0 in.
All pipe joints and connections should be sealed with pipe clamps or other
mechanical means, to insure a leak free outside air connection.
Long runs of pipe and excessive elbows for outside air should be avoided.
Due to frictional resistance in pipe, any excessive outside air piping can
result in poor stove performance.
A screen or other protection device must be fitted over the outside air
termination point to prevent rain, debris and nuisance animals from
entering the piping system.
Increase the outside air pipe size to 3.0 in. diameter pipe if the outside air
connection is more than 6 ft. in length, more than two (2) elbows are used
or if the stove is installed in a basement.
The outside air connection system should be inspected at least annually to be
certain it is free from blockage.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR
OUTSIDE AIR HOOK‐UP
NEVER draw outside combustion air from:
1. Wall, floor or ceiling cavity.
2. Enclosed space such as an attic, garage or crawl space.
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
Caution
15