 The use of outside combustion air is mandatory on this pellet stove. 
 The outside air connection pipe protrudes from the lower rear center of the stove; 
use the included outside air kit to attach your stove to outside combustion air.  
Instructions and all the parts needed to make the outside air connection to your 
pellet stove are included with the outside air kit. 
 If it is not feasible to use the included outside air hookup kit in your stove 
installation, other materials may be used, provided the following rules are followed: 
 The pipe used for outside air hookup must be metal, with a minimum 
thickness of .0209 in. (25 gauge mild steel) or greater and an inside diameter 
of approximately 2.0 in. 
 All pipe joints and connections should be sealed with pipe clamps or other 
mechanical means, to insure a leak free outside air connection. 
 Long runs of pipe and excessive elbows for outside air should be avoided.  Due 
to frictional resistance in pipe, any excessive outside air piping can result in 
poor stove performance. 
 A screen or other protection device must be fitted over the outside air 
termination point to prevent rain, debris and nuisance animals from entering 
the piping system. 
 Increase the outside air pipe size to 3.0 in. diameter pipe if the outside air 
connection is more than 6 ft. in length, more than two (2) elbows are used or if 
the stove is installed in a basement. 
 The outside air connection system should be inspected at least annually to be certain 
it is free from blockage. 
 
 
2. Enclosed space such as an attic, garage or crawl space. 
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
OUTSIDE AIR HOOK‐UP 
Caution 
NEVER draw outside combustion air from: 
1. Wall, floor or ceiling cavity. 
QUESTIONS.