scrolling message; the user can adjust the control board and it will display the adjustment and
then revert back to the scrolling message until the user shuts the unit down.
"Weekly maintenance reminder" ‐ After 7 days of cumulative run time, the control board will
display a scrolling reminder message to confirm the user has performed the weekly maintenance
required with "DID YOU PERFORM WEEKLY MAINTENANCE? HOLD ON BUTTON TO CONFIRM".
Again, the message does not affect the unit's operation, and in this case can be cleared by holding
the "ON" button for 3 seconds, at which time the board status will return to its previous state.
NEVER USE GASOLINE, GASOLINE‐TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR
SIMILAR LIQUIDS TO START OR "FRESHEN UP" A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS
WELL AWAY FROM THE HEATER WHILE IN USE. ADDITIONALLY, NEVER APPLY FIRE‐STARTER TO
ANY HOT SURFACE OR EMBERS IN THE STOVE. DO NOT USE CHEMICALS OR FLUIDS
DO NOT BURN FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.
DO NOT BURN GARBAGE; LAWN CLIPPINGS OR YARD WASTE; MATERIALS CONTAINING RUBBER,
INCLUDING TIRES; MATERIALS CONTAINING PLASTIC; WASTE PETROLEUM PRODUCTS, PAINT OR
PAINT THINNERS, OR ASPHALT PRODUCTS; MATERIALS CONTAINING ASBESTOS; CONSTRUCTION
OR DEMOLITION DEBRIS; RAILROAD TIES OR PRESSURE‐TREATED WOOD; MANURE OR ANIMAL
REMAINS; PAPER PRODUCTS, CARDBOARD, PLYWOOD OR PARTICLEBOARD. THE PROHIBITION
AGAINST BURNING THESE MATERIALS DOES NOT PROHIBIT THE USE OF FIRESTARTERS MADE FROM
PAPER, CARDBOARD, SAWDUST, WAX AND SIMILAR SUBSTANCES FOR THE PURPOSE OF STARTING
A FIRE IN AN AFFECTED WOOD HEATER. BURNING THESE MATERIALS MAY RESULT IN RELEASE OF
TOXIC FUMES OR RENDER THE HEATER INEFFECTIVE AND CAUSE SMOKE.
CONTROL BOARD SETTINGS Manual/Automatic Mode
Automatic Mode
Your stove will arrive from the factory programmed in automatic mode. First, make sure the thermocouple wire
is resting loosely outside the back of the stove (so that it is reading the air temperature) in a safe location where
it can't be damaged. It should not rest directly on the floor, or it will pick up the floor temperature. The
thermocouple wire is the "room temperature heat sensor" whereby the control board will read the room
temperature.
In this mode, after initiating the startup sequence, you select the desired room temperature (ranging from 60
to 90 degrees F) by pressing the Up or Down arrows, and the stove will operate the auger feed and blower speed
according to the temperature you have selected.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR
TO START THE FIRE.
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.