Exhaust Blower Cleaning
Although the exhaust blower and blower housing were designed to minimize ash build‐up, some fly‐ash
will still accumulate there throughout the burning season. The amount and type of ash will depend on the
type of pellets and venting system, but generally this accumulation will be mild. If, when cleaning the exhaust
blower, a large accumulation of fly‐ash is found, cleaning the exhaust blower and housing should be
performed monthly or bimonthly to prevent this excess buildup.
Instructions
Before beginning the exhaust blower cleaning procedure, be certain the unit is unplugged and
thoroughly cooled down.
Remove the panel to the left (if facing the stove). See page 49 for panel removal instructions.
Once the panel is off, the exhaust blower will be clearly visible.
Disconnect the venting system from the exhaust blower just enough that you will be able to remove
the exhaust blower from the stove (the rear panel will also need to be removed).
Unplug the two wires which connect the stove wiring harness to the exhaust blower, using the quick
connect plugs. Disconnect the heat sensor that is mounted (with a screw) to the exhaust blower.
Loosen the five (5)
Lift the exhaust blower up and out of the stove. The gasket which seals the exhaust blower to the
exhaust blower tube is fragile, so take extra care when removing the blower. Even when being careful,
though, it is easy to tear this fragile gasket, and since an airtight seal is crucial here, it is best to replace
this gasket (Part # ‐ PU‐CBMG) every time the exhaust blower is removed.
With the exhaust blower removed, use a utility vacuum to remove any ash accumulation in the exhaust
blower tube.
Use a soft paint brush and carefully remove any ash accumulation from the inside of the exhaust
blower, and from the exhaust blower fan blade.
Inspect the exhaust blower motor for dust accumulation and carefully remove it, ensuring that all air
cooling holes into the motor are open and free of dust deposits.
Install the blower in the reverse order as described above. Remember to check the condition of the
exhaust blower gasket and to replace the heat sensor onto the exhaust blower.
Reinstall the venting system and panels.
Convection Blower Cleaning
As always, be certain the stove is cool and unplugged before servicing any components within the unit.
Since the convection blower does not handle any by‐products of combustion, it does not require serious
cleaning like the exhaust blower. However, dust from the home and other debris in the air can accumulate on
the blades of the convection blower. The convection blower is located in the middle of the stove. Any dust
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR
YEARLY MAINTENANCE
5
/
" self‐drilling screws which hold the exhaust blower to the exhaust blower tube.
16
REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
35