Pan/Tilt Control Panel AW-RP400
Parts and their function
w Front panel
EXT CONT [M/S] switch
This switch is normally kept at the [M] (master) position.
When an additional AW-RP400 has been installed, set
the EXT CONT switch on the additional unit to [S] (slave).
If no additional AW-RP400 is going to be installed, the
EXT CONT switch on this control panel must be kept at
the [M] (master) position without fail.
OPERATE lamp
This lights up green when the ( ) OPERATE switch is at
ON. It goes off when the switch is set to OFF.
OPERATE [ON/OFF] switch
When this switch is set to [ON], the power supply from
the connected pan-tilt heads to the cameras is turned on,
and system control is enabled.
When it is set to [OFF], the power supply from the
connected pan-tilt heads to the cameras is turned off.
Notes
p The centering of the joystick and zoom switch is
adjusted when the OPERATE switch has been set
to [ON]. Therefore, do not touch the joystick or zoom
switch while this switch is at the [ON] position.
p When an additional AW-RP400 is installed and used,
it will not be possible to exercise control from the slave
control panel unless the OPERATE switches not only
on the slave control panel but on the master control
panel as well are set to [ON]. Remember to set the
OPERATE switch on the slave control panel to [ON]
first before setting the OPERATE switch on the master
control panel to [ON].
INCOM jack
The INCOM (inter-communication) headset is connected
here.
LEVEL control
Use this to adjust the volume of the headset's receiver.
CALL button
When this button is pressed, the buzzer of the connected
control panel sounds, and the CALL button lamp lights.
31 (E)
!