Note: If a user wants to have a period of time during the
day when the pump is not running, any of the SPEEDs
can be programmed to 0 RPM. This will cause the pump
to remain stationary/paused throughout the duration of
that SPEED.
Speed Priorities (Non-External Control)
For schedule duration settings, SPEEDs are prioritized
as follows: SPEED 1 -> SPEED 2 -> SPEED 3. SPEED
1 is the highest priority, while SPEED 3 is the lowest.
The drive will not allow a user to program a schedule
of more than 24 hours. When the 24th hour of duration
is programmed it will take time from the lower priority
speeds in order to add them to the SPEED currently
being adjusted.
Example:
Starting Schedule (Before Adjustment)
SPEED 1 duration = 20 hours
SPEED 2 duration = 2 hours
SPEED 3 duration = 2 hours
If the user reprograms SPEED 1 to run for 23 hours,
SPEED 2 (lower priority speed) will automatically
adjust to a 1 hour duration and SPEED 3 (lowest
priority speed) will adjust to a
End Schedule (After Adjustment)
SPEED 1 duration = 23 hours
SPEED 2 duration = 1 hour
SPEED 3 duration = 0 hours
0 hour duration.
Operating the Pump While Running
If power is connected to the pump motor, pressing
any of the following buttons referred to in this
section could result in the motor starting. Failure to recognize this could
result in personal injury or damage to equipment.
Pressing the Display button will cycle through the current
parameters.
• Speed — current run speed
• Time — current time of day
• Duration — amount of time remaining at the
current run speed
• Watts — amount of watts currently being
consumed
Pressing any of the Speed Buttons ("1", "2", "3", "Quick
Clean") while the pump is running will act as temporary
override. It will run the speed and duration that is
programmed for that button. Once completed it will default
back to the appropriate point in the programmed schedule.
Note: If you adjust the speeds of the schedule while the
pump is running, it will run the adjusted speed for the rest
of the current duration, but will not save the adjustments.
Exception: Speed and Duration adjustments to
QUICK CLEAN will always be immediately saved.
Quick Clean
If running Quick Clean, pressing the "+" or "-" arrows will
change the speed accordingly. Pressing the Quick Clean
button again within 10 seconds of pressing the "+" or "-"
arrows will allow you to adjust the duration of Quick Clean
via the "+" and "-" arrows. These changes will be saved
immediately and are the new defaults for Quick clean.
Pressing the Quick Clean button again will cycle through
the two Quick Clean settings. The pump will exit out of
editing mode if no additional buttons are pressed within 10
seconds.
If Quick Clean is running and you wish to stop the Quick
Clean prior to the duration being completed you can press
and hold the Quick Clean button for 3 seconds and the
pump will return to the appropriate point in the programmed
schedule.
SUPERMAX
VS Variable Speed Pump Installation and User' s Guide
®
9