CONNECTION TO FUEL SUPPLY
To connect the burner to the fuel supply follow the instructions in
the Burner Instruction Manual with respect to the length and positio-
ning of the inlet and outlet oil tubes.
INSTRUCTIONS FOR USE
SWITCHING ON
• Set control knob (1) in position "O".
• Turn on the disconnecting switch on the electric switchboard.
• Set the room thermostat (2) at maximum level and set heat con-
trol knob (1) at position
chamber heats up and then the fan starts.
• If the heater doesn't start after you have completed the above
operations consult the Troubleshooting section of this manual.
If the heater is working normally:
• Set the room thermostat at the desired level.
• Move the adjustable air-head (10) into the desired position.

TURNING OFF

Turn control knob (1) to "O" or turn room thermostat on lowest
setting.
The burner stops while the fan turns itself on and off until the
combustion chamber has completely cooled down.
Warning
Never stop the heater by simply turning off the discon-
necting switch on the electric switchboard. The electri-
cal supply must only be disconnected when the fan has
come to a complete stop.
VENTILATION
When the control knob is turned to the symbol
rates in continuous fan mode.
MAINTENANCE
Warning
The following operations must be carried out by quali-
fied personnel only.
Warning
Before carrying out any maintenance operation the hea-
ter must be disconnected from the mains. Therefore:
• Stop the machine as instructed above
• Turn off the disconnecting switch on the electric swit-
chboard.
• Wait until the heater has cooled.
Cleaning the heat exchanger and the combustion chamber
For the heater to operate efficiently the heat exchanger and com-
bustion chamber must be cleaned after a period of prolonged use and
more frequently if too much soot builds up. Soot builds up when there
is not enough chimney draft, when the fuel is of very poor quality,
when the burner is regulated incorrrectly or when the heater is swit-
ched on and off too frequently. If the heater starts vibrating when it is
turned on there is probably too much soot.
200 mm
Fig.2
. The burner starts up, the combustion
the heater ope-
To reach the internal part of the heat exchanger and the combu-
stion chamber remove the burner (a) and the back lower panel (c) as
well as the exchanger inspection panel (e) and the baffle plates (d):
Remove soot and extraneous material with a vacuum cleaner or tube
cleaner.
a
b
f
CLEANING THE FAN
Remove any dirt or extraneous material from the mesh of the aspi-
ration grill (f) and if necessary clean the propeller with an air-suction
tool.
CLEANING THE BURNER
For the heater to work efficiently the burner must be serviced re-
gularly by an Authorized Service Technician. All cleaning,servicing and
regulation operations must be carried out as indicated in the Burner In-
struction Manual.
TRANSPORTING AND MOVING THE HEATER
To move or transport the heater place it on a raised base and then
lift with a forklift truck. There are no eyebolts or other hooking points.
The unit can be attached to brackets by attaching the side of the unit
not shown in Fig. 1 (G) to the brackets.
Warning
Before moving a unit:
• Turn it off as indicated above.
• Disconnect electricity by pulling out the plug.
• Wait until the heater cools down
Warning
Never try to lift the heater manually.Doing so could re-
sult in physical injury.
17
GB
d
e
c
Fig. 3