3.1 BASIC PROGRAMMING
Display
Basic Function
CF
MOTOR
TYPE:
1
Motors for swing gates
2
Motors for sliding gates
PC
Mixed configuration from a PC/MAC (e.g.: one swing and one slide)
dF
DEFAULT:
Y
Indicates that all the set values are default values.
no
Indicates that at last 1 set value is different from the default values.
Select
LO
OPERATING LOGIC:
E, EP, S, SA, SP, A1, A, AP, At, b, bC, C,
Refer to the specific paragraph for a description of the operating logics.
PA
PAUSE A TIME (only displayed with Automatic logic):
Can be adjusted from
Pb
PAUSE B TIME (only displayed with Automatic logic):
Can be adjusted from
Mn
NUMBER OF MOTORS:
1
= 1 motor
2
= 2 motors
F1
MOTOR 1 POWER:
01
= minimum power
50
= maximum power
F2
MOTOR 2 POWER (only displayed with the
01
= minimum power
50
= maximum power
En
ENCODER USE:
Y
= encoders on both motors
no
= disabled encoders
FA
LIMIT SWITCH WHEN OPENING
PC
=
function):
no
= opening limit switches disabled
01
= the limit switch determines when the movement is stopped
02
= the limit switch determines when deceleration begins
FC
LIMIT SWITCH WHEN CLOSING
PC
=
function):
no
= closing limit switches disabled
01
= the limit switch determines when the movement is stopped
02
= the limit switch determines when deceleration begins
E145
Y
if you wish to restore the default configuration.
00
9.5
to
minutes.
00
9.5
to
minutes.
(only displayed with the
(only displayed with the
Mn
2
=
function):
4
Default
Y
E
CU
30
30
2
(swing)
1
(sliding)
25
25
no
CF
1
CF
no
=
or
CF
1
CF
no
=
or
732783 - Rev.D