Service And Repair; Performance Information - RIDGID TP-4000 Manuel D'utilisation

Masquer les pouces Voir aussi pour TP-4000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TP-4000 and TP-5500 Engine-Driven Utility Pumps

Service and Repair

WARNING
!
Service and repair work on this
pump must be performed by qualified repair personnel.
Pump should be taken to a RIDGID Independent
Authorized Service Center or returned to the factory.
All repairs made by RIDGID service facilities are war-
ranted against defects in material and workmanship.
WARNING
!
When servicing this pump, only iden-
tical replacement parts should be used. Failure to fol-
low these steps may create a risk of flooding, property
damage, fire or other serious injury.
If you have any questions regarding the service or
repair of this machine, call or write to:
Ridge Tool Company
Technical Service Department
400 Clark Street
Elyria, Ohio 44036-2023
Tel: (800) 519-3456
E-Mail: TechService@ridgid.com
For name and address of your nearest Independent
Authorized Service Center, contact the Ridge Tool
Company at (800) 519-3456 or http://www.ridgid.com
Appendix I: Pump Performance Information:
Pump Performance As Related To Discharge Head.
MODEL
HP
TP-4000
4.0
TP-5500
5.5
Pump Losses Due To 100 Feet Of Steel Pipe
PIPE
SIZE
4200
2
9
2.5
3.5
3
1
6
DISCHARGE
HEAD
0'
GPH
9600
GPH
16800
5400
7200
15
25
6
10
2
Ridge Tool Company
20'
5700
14400
9600
43
17
3
6
40'
60'
5100
4500
12000
9000
12000
14400
66
95
27
38
9
13
80'
3900
4620
16800
128
51
17