Operation; Maintenance Instructions; Suggested Parts Replacement Schedule; Pump Storage - RIDGID TP-4000 Manuel D'utilisation

Masquer les pouces Voir aussi pour TP-4000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TP-4000 and TP-5500 Engine-Driven Utility Pumps
NOTICE
!
The Honda engine is equipped with
a low oil shut-off sensor. The engine will shut down
and will not restart if the oil level becomes too low.
7. Fill the engine fuel tank with gasoline. Refer to
engine operating manual for the specific grade of
gasoline and amount required.
WARNING
!
Use caution when handling gasoline.
Refuel in well-ventilated area. Never refuel while
engine is running or hot.

Operation

1. Add water to the priming port on the pump (Figure
3) . Continue adding water until the water level is
approximately 3 inches from the top. Install the
priming pump plug. The water in the pump will cre-
ate the suction that primes the pump.
CAUTION
!
• Do not run pump dry. Water is required to lubricate
the shaft seal.
• Pumping chemicals or corrosive liquids with this
pump may shorten the life of the pump, be haz-
ardous to operators and will void the warranty.
• Complete pump and piping system MUST be pro-
tected against below freezing temperatures.
Failure to do so will cause serious damage and
voids the warranty. During freezing weather, open
the drain port and allow all the water in the pump
to drain. This will prevent damage to the pump
when the water freezes.
Drain Port
Figure 3
2. Turn fuel valve to "ON" position.
3. Move choke lever to "CHOKE" position.
4. Move throttle lever to "START" position.
5. Pull engine crank until engine starts. Once engine
starts, move choke lever to "RUN" position.
6. The pump may take several minutes to prime.

Maintenance Instructions

!
the engine to cool and remove the spark plug
before performing any maintenance. Such preven-
tative measures reduce the risk of starting the pump
accidentally.
Inlet Strainer
Check inlet strainer for debris that can restrict water
flow into the pump resulting in poor performance. If the
strainer is dirty, clogged or damaged, clean or replace
the strainer.
Lubrication
Before each use, check engine crankcase oil level. If
low, add Honda 4-Stroke Oil or SAE 10W-30 detergent
oil.
!
than that listed above, take pump to a RIDGID
Independent Authorized Service Center or return it to
the factory.

Pump Storage

!
is out of reach of children and people unfamiliar with
this type of equipment. This pump can cause serious
injury in the hands of untrained users.
Priming Port
If the pump will be stored for long periods of time, drain
the water from the pump and follow the engine manu-
facturer's recommendations for long-term storage.

Suggested Parts Replacement Schedule

Refer to engine owners manual for engine mainte-
nance intervals.
Replace inlet flapper valve every 2 years.
Replace impeller every 2 years.
Replace seal kit every 2 years.
Replace Engine every 1000 hours.
See page 7 for RIDGID Cat. numbers.
Ridge Tool Company
WARNING
Always shut off the engine, allow
CAUTION
If any maintenance is required other
WARNING
Store the pump in a locked area that
5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tp-5500

Table des Matières