Napoleon Fireplaces BL36NTE Instructions D'installation Et D'opération page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

18
Simple venting configurations.
EN
For vent configurations requiring more than two 90° elbows the following formulas apply:
Formula 1: H
< 3V
T
Formula 2: H
+ V
T
Example:
V
= 2 FT (0.6m)
1
V
= 1 FT (0.3m)
2
V
= 1.5 FT (0.5m)
3
V
= V
+V
+V
= 2FT (0.6m) + 1FT (0.3m) + 1.5FT (0.5m) = 4.5FT (1.4m)
T
1
2
3
H
= 6 FT (1.8m)
1
H
= 2 FT (0.6m)
2
H
= H
+ H
= 6FT (1.8m) + 2FT (0.6m) = 8 FT (2.4m)
R
1
2
H
= .03 (four 90° elbows - 90°)
O
= .03 (360° - 90°) = 8.1 FT (2.5m)
H
= H
+ H
= 8FT (2.4m) + 8.1FT (2.5m) = 16.1FT (4.9m)
T
R
O
H
+ V
= 16.1FT (4.9m) + 4.5FT (1.4m) = 20.6 FT (6.3m)
T
T
Formula 1:
Since this formula is not met, this vent configuration is unacceptable.
Formula 2:
Since only formula 2 is met, this vent configuration is unacceptable and a new appliance location or vent configuration
will need to be established to satisfy both formulas.
W415-1442 / D / 12.01.16
REQUIRED
VERTICAL
RISE IN FEET
(METERS) V
T
< 40 feet (12.2m)
T
H
< 3V
T
T
3V
= 3FT (0.9m) x 4.5FT (1.4m) = 13.5FT (4.1m)
T
16.1FT (4.9m) > 13.5FT (4.1m)
H
+ V
< 40 feet (12.2m)
T
T
20.6FT (6.3m) < 40 (12.2m)
(H
) > (V
)
T
T
See graph to determine the required vertical rise V
required horizontal run H
20 (6.1)
19 (5.8)
10 (3.1)
T
3 (0.9)
0
5
(1.5)
(3.1)
HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS) H
The shaded area within the lines represents acceptable
values for H
90°
V
1
.
T
25
10
15
20
(7.6)
(4.6)
(6.1)
and V
T
T
90°
H
2
H
V
1
2
90°
18.1_2B
for the
T
30
(9.1)
T
V
3
90°