WIRING DIAGRAM
Radio
433MHz
PHO1
close/schliessen/fermer/sluiten
PHO2
close/schliessen/fermer/sluiten
close/schliessen/fermer/sluiten
open/öffnen/ouvrir/open

TECHNICAL DATA OF CONTROL BOARD

Voltage:
Transformer:
Output Motor:
Consumption max.:
Consumption Standby:
Operating temperature:
Modes:
Measurements:
Protection class Box:
Fuse:
Remote control:
feasible frequencies:
Ω
8.2 k
+
+
+
+
230 V~ / 50 Hz ±10%
230 V / 24 V, 105 VA
24 VDC
max. 400 W (in operation)
max. 4 W (without accessories)
-20º C ÷ 55º C
Standard, Automatic
145 x 110 mm (without box)
IP45
2 x 2 A (slow-blow fuse)
max. 180 x Rolling Code
433 MHz, 868 MHz
+ +
Model
CM475
The motor control unit is a highly modern electronic unit controlled by
a microprocessor. It has all wiring facilities and functions required for
safe operation. The electronics provides an ideal and matching
closing force. When installed and adjusted correctly the gate can be
stopped manually. During operation, the gate can be stopped via
remote control, push-button or key-switch. The gate requires a firm
stop for "OPEN" and "CLOSED" position.
Humidity and water destroy the control board. Make sure under
all circumstances that water, humidity or dammed-up water cannot
penetrate the control board covering. All openings and cable entries
must be sealed watertight.
L
PE
N
230V~
+/- 10%
50Hz