Electrical and Wiring

For track mounting, see Electrical and Wiring step 6 in the Installation Manual.
Electrical and Wiring 6 - Install the Protector System
Be sure power is NOT connected to the garage door opener BEFORE installing the safety reversing sensor.
To prevent SERIOUS INJURY or DEATH from closing garage door:
Correctly connect and align the safety reversing sensor. This required safety device MUST NOT be
l
disabled.
Install the safety reversing sensor so beam is NO HIGHER than 6" (15 cm) above garage floor.
l
IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSORS
The safety reversing sensors must be connected and aligned correctly before the garage door opener will
move in the down direction.
The safety reversing sensors can be attached to the door track, the wall, or the floor. The sensors should be no more
than 6" (15 cm) above the floor. If the door track will not support the sensor bracket a wall installation is
recommended. Choose one of the following installations.

Wall Installation

Position sensor brackets (P) on wall. Make sure safety reversing sensors are no more than 6" (15 cm) above the floor
and the light beam is unobstructed. Mark and drill 3/16" pilot holes. Attach with lag screws (not provided). NOTE: If
additional clearance is needed, wood blocks or extension brackets (not provided) can be used.

Floor Installation

Measure distance "X" to position both sensor brackets the same distance from the wall. Make sure the light beam is
unobstructed. Attach sensor brackets (P) to the floor using concrete anchors (not provided).
To continue, to Electrical and Wiring step 7 in the
Installation Manual
®
10
Wall Installation
3/16"
Lag Screws
Pre-Drill
(not provided)
P
No more than
6" (15 cm)
Floor Installation
X
Wood Block
(Not Provided)
Extension Bracket
(Not Provided)
Concrete Anchors
(not provided)
P
No more than
6" (15 cm)