IKAR DB-A1 Mode D'emploi page 13

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 20
4. Creation of operational readiness for securing persons
Set up the tripod vertically (Illus. 5).
Fold legs outwards by pressing on the
locking pin (Illus. 6) and pivoting the leg
outwards until you hear it snap in.
Fold legs outwards by pressing on the
locking pin 1 (Illus. 6) and pivoting the leg
outwards until you hear it snap in.
In order to adjust the height of the individual
extendable legs, unlock the locking pin
by pressing with the thumb (Illus. 7) and
sub-sequently pulling it out.
Extend the legs to the desired length and
secure the latter with locking pins. Repeat
this procedure for the remaining 2 legs.
Finally, align and position the tripod. Ensure
safe stand.
To disassemble the tripod, repeat the above
procedure in reverse order.
5. Attachment points according to EN 795: 2012 Typ B
The attachment points (Illus. 8) is suited for attaching fall protection
systems according to EN 360 and in combination with safety harnesses
according to EN 361 for a maximum of 2 persons.
ENGLISH
Illus. 5
Illus. 6
Illus. 7
The fixtures for the IKAR HRA fall protection device
and the ALKO load winch displayed and mounted in
illustrations 5 and 6 are optional accessories.
Illus. 8
13
2 attachment points

Publicité

Table des Matières
loading

Table des Matières