§4.5 - For all mounting variations...
At the other end of the (+) battery cable, mount the 250A
main fuse as close as possible to the vehicle batteries.
Fit it in a location that is fully protected from adverse
weather conditions. Connect the (+) battery cable coming
from the power pack of the HTL to the main fuse, and link
the main fuse to the (+) battery pole. [See Fig. 4.1 - 4.4]
Tighten all electric connections at both ends of
the (+) battery cable thoroughly. Take special
care of the locking nuts of the fuses.
Loose & insufficient fitting can lead to bad con-
tact and overheating of the fuse, followed by
premature failing of the power circuit.
Apply a thick layer of anti-corrosive grease or
Vaseline to all electric connections. [See Fig.
1.3]
In case of battery charging systems, follow the
fitting instructions and electric wiring diagrams of the
vehicle manufacturer regarding the wiring and fuses.