Tighten all electric connections thoroughly.
Loose & insufficient fitting can lead to bad con-
tact and overheating of the fuse, followed by
premature failing of the power circuit.
Apply a thick layer of anti-corrosive grease or
Vaseline to all electric connections. [See Fig.
1.3]
Where reference is made to (+) battery cables and (-)
earth cables, the following minimum cable sections are
recommended:
Table 1.1 - Recommended MIN. cable sections for
(+) battery cables and (-) earth cables
HTL capacity
Cable section
300 - 1000 kg
25 mm²
< 7m cable length
500 - 1000 kg
35 mm²
> 7m cable length
1500 - 3000 kg
35 mm²
> 3000 kg
50 mm²