3.5 External Day/Night Control
Is connect to an external sensor to receive day/night detection signals.
Day/Night
GND (red)
EXT-OUT (white)
3.6 RS-485 Connection
Connecting to the RS-485: The camera can be controlled remotely by an external device or control system, such as a control keyboard,
using RS-485 half-duplex. Connect market Rx+, Rx- to Tx+, Tx- of the RS-485 control system.
RS-485
RS-485(-) (pink)
External sensor switch ON/OFF
Day
EXT-IN (gray)
Night
RS-485(+) (black)
NOTE: To validate the sensor inputs,
open
closed
3
select Function menu B/W
mode the EXT.