OPERATION
Wattage Reference
Tool or Appliance
Incandescent Lights
(4 Quantity x 75 Watts)
TV (Tube Type)
Sump Pump (1/3 hp)
Refrigerator or Freezer
Well Pump (1/3 hp)
Furnace (1/2 hp)
Radio
Drill (3/8", 4 amps)
Circular Saw
(Heavy Duty, 7-1/4")
Miter Saw (10")
Table Saw (10")
*Wattages listed are approximate. Verify actual wattage.

EXTENSION CORDS

Asphyxiation hazard. Extension cords running directly
into the home increase the risk of carbon monoxide
poisoning through any openings. If an extension cord
running directly into your home is used to power indoor
items, there is a risk of carbon monoxide poisoning to
people inside the home. Always use battery-powered
carbon monoxide detector (s) that meet current UL 2034
safety standards when running the generator. Regularly
check the detector (s) battery.
Asphyxiation hazard. When operating the generator with
extension cords, make sure the generator is located in
an open, outdoor area, far away from occupied spaces
with exhaust pointed away.
Fire and electrocution hazard. Never use worn or
damaged extension cords. Damaged or overloaded
extension cords could overheat, arc, and burn resulting
in death or serious injury.
Before connecting an AC appliance or power cord to the
generator:
• Use grounded 3-prong extension cords, tools, and
appliances, or double-insulated tools and appliances.
• Make sure the tool or appliance is in good working
order. Faulty appliances or power cords can create a
potential for electric shock.
Estimated
Estimated
Running
Starting
Watts*
Watts*
300
300
800
700
1000
800
200
440
1400
1800
2000
WARNING
WARNING
WARNING
• Make sure the electrical rating of the tool or appliance
does not exceed the rated power of the generator or the
receptacle being used.
EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for
0
outdoor use that are rated for the electrical load.
0
1300
2200
2000
Total
2350
Amperage
0
Up to 10A
600
2300
Up to 15A
1800
2000
Up to 20A
Up to 30A
Up to 35A

ST SWITCH

The wGen7500DF is compatible with the ST Switch,
purchased separately. When utility power is on it will
provide power (up to 120V @ 20A) to the appliances
plugged into the 5-20R receptacle on the ST Switch. When
utility power is lost the ST Switch automatically transfers
input power from utility to generator power. When utility
power is restored, the ST Switch transfers input power
back to utility. Visit www.westinghouseoutdoorpower.com
for more information.
Westinghouse Outdoor Power Equipment, LLC | 21
Minimum Gauge, Outdoor Rated
Up to 50 FT (15 M)
Up to 100 FT (30 M)
1
12
10
1
10
8
6
8
8
6
6
6