Troubleshooting Guide - England's Stove Works 25-IP Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

 
WARNING: To avoid ELECTRICAL SHOCK always disconnect the unit from the power source BEFORE  
attempting any repair.  If this guide does not correct the problem, call your local dealer or Technical 
Problem 
Auger not turning 
  
  
Smoke smell or dust in house 
Room blower not operating 
  
  
Exhaust blower not operating 
  
  
Lazy Fire 
  
  
  
Blown Fuse 
  
  
High Pellet Consumption 
Squeaking Noise 
  
Pinging or Rattling Noise 
  
"E‐1" Code On Control Board 
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
Trouble‐Shooting Guide
Support at 1‐800‐245‐6489. 
Cause  
1. Bad auger motor. 
2. Foreign matter jamming auger. 
3. Vacuum sensor. 
1. Improper exhaust connection. 
1. Loose thermal sensor. 
2. Blower speed set higher than heat 
range, causing stove to cool and blower 
to cycle. 
3. Loose connection. 
1. Loose connection. 
2. Bad blower. 
3. Bad vacuum sensor. 
1. Bad exhaust blower. 
2. Excessive pellet moisture. 
3. Excessive ash build‐up. 
4. Low quality pellets. 
1. Power surge. 
2. Exposed wire. 
3. Electrical component shorting. 
1. Low quality or non‐uniformly sized 
pellets. 
1. Obstruction in auger tube. 
2. Blower Noise. 
1. Foreign material in blower. 
2. Loose exhaust fan set screw. 
1. N/A  on this unit. 
32
QUESTIONS.
Solution 
1. Replace auger motor. 
2. Remove pellets and object. 
3. Check exhaust blower. 
1. Check exhaust connections for 
leaks, especially the exhaust blower 
connect.  Seal leaks with silicone, 
aluminum tape or a hose clamp. 
1. Tighten connection on sensor. 
2. Lower blower speed. 
3. Check control board connection. 
1. Check control board connection. 
2. Replace blower. 
3. Replace vacuum sensor. 
1. Inspect and replace blower. 
2. Keep pellets dry. 
3. Thoroughly clean unit. 
4. Use only PFI premium pellets. 
1. Replace fuse; use surge protector. 
2. Check for exposed or frayed wire 
and loose connections. 
3. Check motors and blowers for 
obstructions or short circuits. 
1. Use premium pellets or try 
another pellet brand. 
1. Check auger tube for foreign 
objects. 
2. Remove, clean, and oil blower. 
1. Check both blowers for material. 
2. Check set screw for tightness. 
1. Contact Technical Support. 