A) MIN. 4‐FT CLEARANCE BELOW OR BESIDE ANY DOOR OR WINDOW THAT OPENS.
B) MIN. 1‐FT CLEARANCE ABOVE ANY DOOR OR WINDOW THAT OPENS.
C) MIN. 2‐FT CLEARANCE FROM ANY ADJACENT BUILDING.
D) MIN. 7‐FT CLEARANCE FROM ANY GRADE WHEN ADJACENT TO PUBLIC WALKWAYS.
E) MIN. 2‐FT CLEARANCE ABOVE ANY GRASS, PLANTS, OR OTHER COMBUSTIBLE MATERIALS.
F) MIN. 3‐FT CLEARANCE FROM A FORCED AIR INTAKE OF ANY APPLIANCE.
G) MIN. 2‐FT CLEARANCE BELOW EAVES OR OVERHANG.
H) MIN. 1‐FT CLEARANCE HORIZONTALLY FROM COMBUSTIBLE WALL.
I) V
ENTS INSTALLED WITH MECHANICAL EXHAUSTERS SHALL TERMINATE NOT LESS THAN
HIGHEST POINT WHERE THEY PASS THROUGH THE ROOF SURFACE
Notes on termination of Pellet Vent Pipe from
(See also "INSTALLATION" section of manual AND additional notes above):
-
Not less than three (3) feet above any forced air inlet located within ten (10) feet.
-
Not less than four (4) feet below, four (4) feet horizontally from, or one (1) foot above any door,
window or gravity air inlet into any building.
-
Not less than two (2) feet from an adjacent building, and not less than seven (7) feet above
grade where located adjacent to public walkways.
The exhaust exit shall be arranged so that the flue gases are not directed so that it will affect people,
overheat combustible structures, or enter buildings. Forced draft systems and all parts of induced
draft systems under positive pressure during operation shall be installed gastight or to prevent
leakage of combustion products into a building. Through-the-wall vents shall not terminate over
public walkways, or where condensate or vapor could create hazards or a nuisance.
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
Be sure to follow local codes and all manufacturer's instructions (including exhaust pipe).
ENGLAND'S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
Consult a professional installer and/or call Technical Support if you have any questions.
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
VENT TERMINATION CLEARANCES
NFPA 211 (2006 ed.) Section 10.4 Termination: 10.4.5
QUESTIONS.
.
14
12
.
(305
)
IN
MM
ABOVE THE