CARE AND MAINTENANCE
CARE AND MAINTENANCE
IMPORTANT:
1) Be sure to unplug the unit before cleaning or servicing.
2) Do not use gasoline, thinner or other chemicals to clean
Air filter
(take out)
3) Do not wash the unit directly under a tap or using a hose.
4) If the damaged power supply cord must be replaced with
Fig.24
1. Air filter
-
-
-
Air filter
(install)
-
Fig.25
NOTE: The grill and the air filter are connected and can be
2. Unit enclosure
-
3. Unit idle for a long time
-
-
-
-
-
the unit.
It may cause electrical danger.
a new power supply cord obtained from the product
manufacturer and not repaired.
Clean the air filter at least once every two weeks to prevent
inferior fan operation because of dust.
Removal
Take the air filter out along the arrow direction (Fig.24).
Cleaning
Wash the air filter by immersing it gently in warm water
O
O
(about 40
C/104
F) with a neutral detergent. Rinse the filter
and dry it in a shady place.
Mounting
Install the air filter after cleaning (see Fig.25).
separated.
Use a lint-free cloth soaked with neutral detergent to clean
the unit enclosure. Finished by a dry clean cloth.
Remove the rubber plug at the back of the unit and attach
a hose to drain outlet
. Place the open end of the hose
directly over the drain area in your basement floor
(See Fig.22 & 23).
Remove the plug from the bottom drain outlet, all the water
in the bottom tray would drain out (See Fig.24).
Keep the appliance running on FAN mode for half a day in
a warm room to dry the appliance inside and prevent mold
forming.
Stop the appliance and unplug it, wrapped the cord and
bundle it with the tape. Remove the batteries from
the remote controller.
Clean the air filter and reinstall it.
14
TROUBLE SHOOTING
TROUBLES
POSSIBLE CAUSES
1. Unit does not
- P1 appears in the display window
Start when
Pressing on/off
- Room temperature is lower than
Button
the set temperature.(Cooling mode)
- The windows or doors in the room
are not closed.
- There are heat sources inside the
2. Not cool enough
room.
- Exhaust air duct is not connected or
blocked.
- Temperature setting is too high.
- Air filter is blocked by dust.
4. Noisy or vibration
- The ground is not level or not flat
enough.
5. Gurgling sound
- The sound comes from the flowing
of the refrigerant inside the
air-conditioner.
- The automatic over heat
protection function. When the
6. Power shut off at
temperature at the air outlet
Heating mode
exceed 70
wi ll stop.
TROUBLESHOOTING TIPS
SUGGEST REMEDIES
Drain the water in the bottom tray.
Reset the temperature.
Make sure all the windows and
doors are closed.
Remove the heat sources if possible.
Connect the duct and make
sure it can function properly.
Decrease the set temperature.
Clean the air filter.
Place the unit on a flat, level
ground if possible.
It is normal.
Switch on again after the unit
has cool down.
O
O
C/158