Installation Instructions; Location; Window Kit Installation - Climadiff CLIMA18 Manuel D'utilisation

Masquer les pouces Voir aussi pour CLIMA18:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATING INSTRUCTIONS
Adjust
manually
Adjust
Fig.4
Other features
Auto-Restart
If the unit breaks off unexpectedly due to the
power cut,it will restart with the previous
function setting automatically when the powe
resumes..
Wait 3 minutes before resuming operation
After the unit has stopped, it cannot be restarted
operation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
POWER MANAGEMENT feature
When the ambient temperature is lower than the
setting temperature for a period of time, the unit
will be automatically operate power management
feature. The compressor and fan motor stop.
When the ambient temperature is higher than the
setting temperature, the unit will be automatically
quit the power management feature. The
compressor and (or) fan motor run.
Air flow direction adjustment
(Fig.4):
The louver can be set to the desired position
manually.
Do not place any heavy objects or other loads
on the louver, doing so will cause damage to
the unit.
Ensure the louver is fully opened under
Keep the louver fully opened during
operation.
8
INSTALLATION INSTRUCTIONS (optional)
or
Fig.5
Horizontal
window
Window Slider Kit
Minimum:67.5cm(2.22ft).
Maxmum:123cm(4.04ft).
or
Horizontal
window
Window Slider Kit
Minimum:67.5cm(2.22ft).
Maxmum:123cm(4.04ft).
Horizontal
window
Window Slider Kit
Maxmum:123cm(4.04ft).
or
Horizontal
window
Window Slider Kit
Minimum:67.5cm(2.22ft).
Maxmum:123cm(4.04ft).
Fig.7

INSTALLATION INSTRUCTIONS

Location

The air conditioner should be placed on a firm
foundation to minimize noise and virbration. For safe
and secure positioning, place the unit on a smooth,
level floor strong enough to support the unit.
The unit has casters to aid placement, but it should
only be rolled on smooth, flat surfaces. Use caution
when rolling on carpet surfaces.
Do not attempt to roll the unit over objects.
The unit must be placed within reach of a properly
rated grounded socket.
Never place any obstacles around the air inlet or
outlet of the unit.
Allow at least 30cm of space from the wall for
efficient air-conditioning.
Window Slider kit Installation
Your window slider kit has been designed to fit most
standard "Vertical" and "horizontal"window
applications, However, it may be necessary for you to
improvise/modify some aspects of the installation
procedures for certain types of window. Please refer
to Fig. 6& Fig.7 for minimum and maximum window
openings.Window slider kit can be fixed with a bolt
(see Fig.7a).
Note: If the window opening is less than the mentioned
minimum length of the window slider kit, cut that one
never cut out the hole in window slider kit.
bolt
bolt
or
Window
Window slider kit
slider kit
Fig.7a
9

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Clima19

Table des Matières