Daikin Altherma EHS04P30B Instructions D'installation Et D'utilisation page 158

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 164
10
x
Technical data
R
Sensor resistance (NTC)
S
t
Temperature
t
Storage tank temperature sensor
DHW2
t
Return flow temperature sensor
R2
t
Flow temperature sensor
V1
t
Flow temperature sensor Backup-Heater
V, BH
Fig. 10-1 Characteristics of the NTC temperature sensor Daikin
Altherma EHS(X/H) - part 1
t
;
AU
t
DHW1
R
Sensor resistance (NTC)
S
t
Temperature
t
External temperature sensor RoCon OT1
AU
t
Storage tank temperature sensor
DHW1
Fig. 10-2 Characteristics of the NTC temperature sensor Daikin
Altherma EHS(X/H) - Part 2
f
Frequency
m
Flow
Fig. 10-3 Characteristics of the flow sensor FLS (V1) Daikin Altherma
EHS(X/H)
Installation and operating instructions
76
R
Sensor resistance (Pt 1000))
S
t
Temperature
t
Return flow temperature sensor in the flow meter
R1
Fig. 10-4 Characteristics of the return flow temperature sensor in the
flow sensor FLS (t
) Daikin Altherma EHS(X/H)
R1
p
Water pressure
U
Tension
Fig. 10-5 Characteristics of the pressure sensor (DS) Daikin Altherma
EHS(X/H)
Daikin Altherma EHS(X/H)
Daikin Altherma integrated solar unit
008.1441399_02 – 01/2021 – EN

Publicité

Table des Matières
loading

Table des Matières