NOTA
CHAUFFAGE ELECTRIQUE
IMPORTANT :
The 2 algorhythms adjust the time between 2 defrosting
cycles in order to optimise the performance of the air
conditioning unit.
The algorhythm will automatically increase the time
between 2 defrosting cycles and reduce the cycles,
depending on requirements.
For appliances equipped with electric heating :
The electric heating in the heatpump systems is forced
for heating and ventilation, and the treatment unit will
operate at low speed in relation to the evaporator
sensor values and in accordance with the difference
between the ambient air temperature sensor value and
the set temperature.
N.B.
(The OPER or green diode on the infrared receiver
flashes when the outside fan is stopped.)
For appliances not equipped with electric heating :
The treated air fan motor stops running during the
defrosting cycles, so as to avoid an uncomfortable
flow of cold air being discharged into the premises.
This operation is compatible with outside temperatures
above 0°C.
ELECTRIC HEATING
Electric heating may be connected to the heatpump
model as an addition to the standard thermodynamic
heating of the appliance.
IMPORTANT :
- Connections as indicated on the diagrams should
be respected.
25