3.3 ELECTRICAL WIRING
WARNING
DO NOT EXCHANGE NEUTRAL WITH PHASE
~
50Hz 230V
PE
L
N
Limit thermostat
with manual
resetting
7 pin plug
7 pole socket
Ignition
electrodes
ACCESS TO THE PHOTORESISTANCE
(See fig. 9)
The photoresistance is fitted directly into the con-
trol-box (underneath the ignition-transformer) on a
plug-in support.
2686
Main switch
T6A
Regulating
thermostat
Black
White
Blue
Burner-earth
Photoresistance
NOTES:
– Wires of 1 mm 2 section .
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in the
Country.
Hour counter
(230V - 0.1A max.)
Remote lock-out lamp
(230V - 0.5A max.)
Motor
Capacitor
Oil valve
D1846
Ignition
transformer
Photoresistance
5
GB
TESTING
Check the shut-down of the
burner by opening the ther-
mostats.
CONTROL BOX
To remove the control-box
from the burner, loosen screw
(A, fig. 8) and pull to the arrow
direction, after removing all
components, the 7 pin plug
and earth wire.
Fig. 8
E9157
A
Fig. 9
E9102