TECHNICAL DATA

Technical data
Supply voltage:
Power consumption:
Input and output signal:
Switching capacity:
Smallest load:
Controlled storage heaters:
Device fuse:
Connecting terminals:
Ambient temperature:
Protection class:
Degree of protection:
Standard:
Space required:
Mounting:
8 | ZSE 5
230 V AC, 50 Hz
approx. 2 VA
oscillation package controlled alternating voltage,
cycle time approx. 10s
230 V AC, 0.7 A, corresponding to 160 W
dependent on device type
G fuse link F2 according to DIN 41660 (2 A fast,
spare fuse in the device socket)
5 Nm
0 °C to 50 °C
II if installed properly
IP 00 according to DIN 40050
DIN 44574 and DIN 57631 / VDE 0631
3 horizontal pitch units according to DIN 43880
top hat rail according to DIN EN 50022