Operation - Stiebel Eltron ZSE 5 Utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation

Setting the charging level
With the E5 adjuster of the group control unit you can in-
crease the target charge rate of the central control unit for
the connected living area by up to 10% or reduce it by up to
30%.
If more charging than the central setting is required (i.e. the
storage heaters contain no sufficient heat at the end of the
day), E5 should be increased. If the room temperature is too
high, E5 should be decreased.
Changes made via the E5 adjuster will only be noticeable the
next day. To avoid incorrect settings, E5 should only be
changed in small steps.
www.stiebel-eltron.com
Corrections to the basic settings:
Problem
Correction of setting
Set adjuster E5 to the "+" range by at least
Too little charge
5%
Set adjuster E5 to the "-" range by at least
Too much charge
5%
OPERATION
ZSE 5 | 7