output performance of the relay
X 0 = H1 switches at 0
0 X = H2 switches at 0
X 1 = H1 switches at preset
1 X = H2 switches at preset
X 2 = H1 switches at ≥ preset, de-energises at < preset
P11
2 X = H2 switches at ≥ prese, de-energises at < preset
X 3 = H1 switches at ≤ preset, de-energises at > preset
3 X = H2 switches at ≤ preset, de-energises at > preset
0 4 = H1 switches at 0 and sets autopreset (preset 1)
4 0 = H2 switches at preset 1 - preset 2
0 5 = H1 switches at preset 1 and sets autoreset (0)
fleeting time relay H1
P12
0.1s ... 9.9s adjustable in steps of 0.1s
fleeting time relay H2
P13
0.1s ... 9.9s adjustable in steps of 0.1s
display brightness
P14
0 ... 9 = level of brightness
external reset/preset
P15
0 = preset if pulse on terminal 13
1 = reset if pulse on terminal 13
basic setting
P16
1 = all parameter values are set to the basic setting
input block for preset
P18
0 = preset can be changed
1 = preset cannot be changed (blocked)
limitation of the counting frequency in the VRD mode
0 = max. counting frequency =10 Hz
P19
(max. count value: ± 32768)
1 = max. counting frequency = 20 kHz
relay switches if value of the preset value is positive or
P21
negative
0 = active; 1 = not active
display of the current software version and the version
P99
number
For programming terminals 6 and 7 must be linked, e.g. by means of
a key switch.
If no key is pressed during the programming/setting process for
approx. 15s, the unit will change into the operating mode with
unchanged parameter values.
12
1 1
1,0
1,0
5
1
0
0 0
(V1 = 0
V2 = 0)
1 1
(IN-A = 1
IN-B = 1)
1