BTL7-A/C/E/G_ _ _-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S135/KA_ _
Micropulse Transducer - Rod Style
4
Installation and connection (continued)
4.4.3
Connector type S135
Pin
-A_10
-G_10
1
0 to 10 V
-10 to 10 V
2
10 to -10 V
3
10 to 0 V
4
0 V (pin 3)
BTL7-_1_ _-...
5
20 to 28 V
6
GND
2)
Unassigned leads can be connected to the GND on the controller side but not to the shield.
1)
2)
Reference potential for supply voltage and EMC-GND.
Tab. 4-4:
Connection assignment BTL7...-S135
4.4.4
Cable connection KA_ _
Cable color
-A_10
YE yellow
Not used
GY gray
PK pink
10 to 0 V
10 to -10 V
RD red
-10 to 10 V
GN green
0 to 10 V
WH white
BTL7-_1_ _-...
BU blue
BN brown
20 to 28 V
Unassigned leads can be connected to the GND on the controller side but not to the shield.
1)
2)
Reference potential for supply voltage and EMC-GND.
Tab. 4-5:
Connection assignment BTL7...-KA_ _
4.5

Shielding and cable routing

Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Connect the transducer and controller using a shielded
cable.
Shielding: Copper filament braided, at least 85%
coverage.
Connector version: Shield is interally connected to
connector housing.
Cable version: On the transducer side, the cable
shielding is connected to the housing.
Ground the cable shielding on the controller side
(connect with the protective earth conductor).
www.balluff.com
-C_00
-C_70
-E_00
0 to 20 mA 20 to 0 mA 4 to 20 mA
0 V (pin 1)
Not used
Not used
BTL7-_5_ _-...
10 to 30 V
-G_10
-C_00
-C_70
0 to 20 mA 20 to 0 mA 4 to 20 mA
1)
0 V
Not used
La (programming input)
Not used
Lb (programming input)
GND
2)
-E_70
20 to 4 mA
1)
Fig. 4-11:
1)
GND
2)
-E_00
-E_70
20 to 4 mA
1)
1)
BTL7-_5_ _-...
GND
2)
10 to 30 V
Magnetic fields
The position measuring system is a magnetostrictive
system. It is important to maintain adequate distance
between the transducer cylinder and strong, external
magnetic fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
Bending radius for fixed cable
The bending radius for a fixed cable must be at least five
times the cable diameter.
Cable length
BTL7-A/G
Max. 30 m
BTL7-C/E
Max. 100 m
Tab. 4-6:
Cable lengths BTL7
Prerequisite: Construction, shielding and routing preclude the effect of any
1)
external noise fields.
Pin assignment of S135 (view of
connector pins of transducer),
6-pin M16 circular plug
1)
1)
english
11