BTL7-A/C/E/G_ _ _-M_ _ _ _-A/B/Y/Z(8)-S32/S115/S135/KA_ _
Micropulse Transducer - Rod Style
8
Calibration using adjustment (continued)
4. Adjust end value
Bring magnet to end position.
Hold down
for at least 2 s.
Indication for "Adjust end value" is displayed.
Adjust end value
The end value can be changed using
Œ
and
. The gradient of the output
1)
is changed, but the zero value remains
unchanged (see page 14).
Exit calibration procedure: Press
more than 2 s.
Indication for "Adjustment" is displayed.
Set position value is saved.
Check values
The settings for the start value and end
value have a mutual effect depending
on the measuring position.
Repeat steps 3 and 4 until the desired
values are exactly set.
5. Exit adjustment and deactivate buttons
Œ
Hold down
and
Output indicates error value.
Œ
Briefly press
or
Buttons are deactivated.
Current position value is displayed.
1) Briefly press button: Current value is increased or
decreased by approx. 1 mV or 1 mA.
If a button is held down longer than 1 s, the step
interval is increased.
18
english
Œ
and
for no
simultaneously for at least 6 s.
(< 1 s).
LED legend:
Adjust
start value
LED display
(see page 17)
LED1 LED2 At 0 to 10 V
> 2 s
2
1
1
2
2
< 2 s
1
2
1
2
> 6 s
< 1 s
1
2
LED not on
LED green
LED 1 and LED 2 flashing red-green in alternation
LED flashing green
LED 1 and LED 2 flashing red-red in alternation
Displayed values (example)
At 4 to 20 mA
9.89 V
19.13 mA
10.00 V
20.00 mA
9.89 V
19.13 mA
9.00 V
19.00 mA
2.00 V
6.00 mA
9.00 V
19.00 mA
10.50 V
3.60 mA
9.00 V
19.00 mA