SeeSnake
recycle rechargeable batteries. Normal and recharge-
able batteries contain materials that should not be di-
rectly disposed of in nature, and contain valuable materials
that can be recycled. Help to protect the environment
and conserve natural resources by returning your used
batteries to your local retailer or an authorized RIDGID ser-
vice center for recycling. Your local recycling center can
also provide you with additional drop off locations.
RBRC™ is a registered trademark of the Rechargeable
Battery Recycling Corporation.
For EC countries: Defective or used battery packs/bat-
teries must be recycled according to the guideline
2006/66/EC.
Chart 1 Troubleshooting
PROBLEM
Camera video image not
seen.
MINI Pak screen is a
steady blue with no
image.
Screen display indicates
MINI Pak battery is low.
Count accuracy seems
unreliable.
(CountPlus)
The symbol "+" appears
after the on-screen dis-
tance measurement.
(CountPlus)
Low Battery warning ap-
pears on screen.
(CountPlus)
12
MINI Pak
®
PROBABLE FAULT LOCATION
No power to SeeSnake.
Connections faulty.
Batteries Low.
No video signal.
MINI Pak 18 V batteries low.
Settings incorrect for reel or cable being used.
Counting from a zero point other than the one in-
tended.
Physical cable measurement has exceeded the
cable parameter in settings.
CountPlus Battery dead or near-dead.
Check power is correctly plugged in.
Check Power Key on MINI Pak by pressing.
Check alignment and pins of connection to MINI Pak
unit from SeeSnake.
Check orientation, seating, and pin condition in the
SeeSnake System connection. Clean if needed.
Recharge batteries; use power supply until bat-
teries are charged.
Re-seat SeeSnake system cable connection.
Recharge or replace MINI Pak batteries. Switch to
external power.
Verify the CountPlus settings are correct for the
SeeSnake cable length, cable diameter and reel
type you are using.
Confirm you are measuring from the intended
zero-point. Reset zero-point using Zero Key (See
page 9).
Verify the actual length of your installed cable; re-set
the reel and cable settings for the correct reel type
and actual cable size as described in the CountPlus
manual.
Replace 3-volt battery in the CountPlus (CR2450).
Ridge Tool Company
SOLUTION