General Instructions; Maintenance By Your Service Retailer (Local Authorized Retailer) - Horus ALMA Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The stove shows
"Thermal
overheating"
The stove shows
"No vacuum"

63.GENERAL INSTRUCTIONS

Switch the stove off and let it cool down at room temperature before carrying out maintenance. Wait for at least
an hour after shutting down the device
WARNING
Always use anti-heat gloves to avoid possible skin burns.
WARNING
Deactivate the back switch by moving it to "0" Unplug the device
WARNING
Do not unplug the device or deactivate the back switch by moving it to "0" when the stove is on. This will block all
the engines in the device and hamper the exhaustion of fumes inside the stove.
WARNING
In case of flue fire, unplug the device, do not open any compartment and immediately contact the fire
department.

64.MAINTENANCE BY YOUR SERVICE RETAILER (LOCAL AUTHORIZED RETAILER)

WARNING
Extraordinary maintenance must be performed by your Service Retailer.
WARNING
Before any type of maintenance, replacing, repairing, cleaning, etc. make sure your stove has no connection
whatsoever to energy power supplies (disconnect the power supply cable from its socket)
Wear appropriate safety devices (e.g. anti-perforation gloves) when carrying out maintenance operations.
Carry out maintenance when the stove is shut down and completely cooled off.
The bimetallic safety
thermostat trips the alarm
Improper installation of the
flue or clogged flue
Pressure switch not working
.
Notice d'installation, d'utilisation et d'entretien
Contact technical assistance
Make sure there are no chimneypots on top of
the flue that are unsuitable for pellet stoves or
clean the flue
Contact technical assistance
57

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

AuraAlma 11.0c–9.0Aura11.0c–9.0

Table des Matières