The stove shows
Smoke temperature control
"Smoke
probes deteriorated
temperature
probe"
The stove shows
Poor exhaust
"Smoke
overheating"
The room fan is blocked or
clogged with dust
The stove shows
The control board cannot
"Smoke Encoder
control the smoke exhaust
faulty"
speed
Smoke exhaust motor
blocked.
The stove shows
No pellets in the tank
"Ignition fail"
Too much ash residue in the
brazier
Igniter malfunctioning
The stove says
No pellets in the tank
"No pellets"
Pellets in the tank but when
the stove is on they do not
drop into the brazier
Notice d'installation, d'utilisation et d'entretien
Contact technical assistance
Check the smoke evacuation airways (flues,
chimneypots)
Check the fan operation, clean any excessive ash
incrustations, and replace if broken.
Contact technical assistance
Make sure the motor has no mechanical
problems (ash accumulations, bearing partially
blocked, combustion chamber door open),
check, clean, replace
Check the motor, check for any ash
accumulations on the internal impeller
Contact technical assistance
Refill the fuel tank
Empty and clean the brazier, clean any clogged
air holes, check the condition of the brazier
Check the terminals, electrical operation, and
replace if not working
Contact technical assistance
Refill the fuel tank
Check the quality of the pellets, check the
bottom of the tank for residue (due to low
quality pellets), make sure the pellets are of
standard length (pellets longer than 2.5 cm are
improperly loaded by the screw feeder, this is
also true of overly short pellets).