36.MENU 04 CHOOSE LANGUAGE
Allows you to choose the language you prefer among the available ones.
37.MENU 05 STAND-BY MODE
Activate the STAND-BY mode which shuts down the stove when the room temperature is above the temperature SET for a period
of time longer than the one defined by Pr44. If the stove shuts down for this reason, you will be able to switch it on only when the
following condition is fulfilled: T set < (room T – Pr43)
38.MENU 06 BUZZER MODE
When OFF it disables the acoustic signalling.
39.MENU 07 INITIAL CHARGE
When the stove is switched off and cold, it allows you to pre-load the pellet for 90". Start up with key P1 and stop with key P4..
40.MENU 08 STOVE STATUS
Displays the current stove status and the status of the devices connected to it. Scroll down to see the different pages available.
41.OPERATING MODE
The standard operating mode of a controller installed on an air stove is described below. The descriptions below refer to a
controller with chrono-thermostat options.
42.SWITCHING THE STOVE ON
Press P4 for a couple of seconds to switch the stove on. The display signals that the stove is switched on.
43.START-UP STAGE
The stove start-up phases are carried out in sequence, following the set time parameters..
44.FAILED SWITCHING ON
After Pr01 time, if the fume temperature hasn't reached 50°C, the alarm goes off.
45.OPERATING STOVE
After having been successfully switched on, the stove shifts to normal working phase. If the fume temperature is higher than
Pr15, heat exchangers are automatically activated.
46.SETTING ROOM TEMPERATURE AND POWER
To set room temperature, select the CHANGE TEMP SET by pressing P2 key. Use P1 and P2 keys. The display shows the status of
the current temperature SET. To set power select the CHANGE POWER SET by pressing P6 key. Use P6 and P5 keys. The display
shows the status of the current power SET..
47.USE OF THERMOSTAT/EXTERNAL CHRONO-THERMOSTAT
You can use an external thermostat. We strongly suggest that you contact a qualified technician for installation.
Thermostat: program a temperature SET of 7°C
External chrono-thermostat: program a temperature SET of 7°C and disable the chrono functions in the menu.
48.WHEN THE ROOM TEMPERATURE HAS REACHED THE SET VALUE
When the room temperature has reached the set value, or the fume temperature gets to Pr13, the heat power is automatically
brought down to minimum value, called MODULATION. If the STAND-BY mode is activated, the stove starts to working again until
Pr13 value is reached. Restart is possible when the above conditions are fulfilled..
49.RESTART AFTER SWITCHING OFF WHEN TEMPERATURE REACHES SET ROOM TEMPERATURE
After the STAND-BY switching off, the stove cools down and the fume exhaustion speed is brought to maximum level. After the
switching off, the stove cools down and the exhaustion speed is brought to the level determined by Pr29. Restart is possible once
the following condition is fulfilled: Room T < (T set - Pr43)
50.CLEANING THE BRAZIER
In normal working conditions and at intervals set by Pr03, the CLEANING BRAZIER mode is activated for a period of time
determined by P12.
Notice d'installation, d'utilisation et d'entretien
53