6. Specifications
Smart BMS CL 12-200
Maximum continuous charge
current
Input voltage to start charging
Current consumption, remote on
Current consumption, remote off
Load disconnect output
Charge disconnect output
Pe-alarm output
System on/off:
Remote L and Remote H
GENERAL
Operating temperature range
Humidity, maximum / average
Protection, electronics
DC power connection
DC connector battery minus
ENCLOSURE
Weight
Dimensions (hxwxd)
STANDARDS
Emission
Immunity
Automotive Directive
10
100A (with 125A fuse)
> 13V
16 mA (excluding Load output and Charge output current)
5 mA (BMS functionality still active)
Normally high (Vbat – 0.1V)
Source current limit: 10mA (short circuit protected)
Sink current: 0A (output free floating)
Normally high (Vbat – 0.1V)
Source current limit: 10mA (short circuit protected)
Sink current: 0A (output free floating)
Normally free floating
High (Vbat) in case of alarm, max. 1A
(not short circuit proof)
Use modes of the system on/off:
a. ON when the L and H terminal are interconnected
b. ON when the L terminal is pulled to battery minus (V< 5V)
c. ON when the H terminal is high (V>3V)
d. OFF in all other conditions
-40°C to +60°C
100% / 95%
IP65
M8
Faston female, 6.3mm
1,6kg
65 x 120 x 224 mm
EN 61000-6-3, EN 55014-1
EN 61000-6-2, EN 61000-6-1, EN 55014-2
ECE R10-5