Glowing Embers; Charcoal Embers; Restricting Vertical Vents; Venturi Adjustment - Napoleon Ascnet X 70 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.8 glowing embers

WARNING
!
Completely blocking the burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed
ignition.
Tear the embers into pieces and loosely layer above the burner ports covering the burner area. Care should be
taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi bre hairs will glow.
The ember material will only glow when exposed to direct fl ame; however, care should be taken to not
block off the burner ports.
Blocked burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. PHAZER™
logs glow when exposed to direct fl ame. Use only certifi ed "glowing embers" and PHAZER™ logs available from
your local authorized dealer / distributor.

10.9 charcoal embers

WARNING
!
Do not block or close off the burner ports. Blocked ports can cause an incorrect fl ame pattern, carbon
deposits and delayed ignition.
When supplied, charcoal embers, charcoal lumps and vermiculite are not to be placed on the burner.
Randomly place the charcoal embers along the front and sides of the log support in a realistic manner.
Fine dust found in the bottom of the bag should not be used.
note:
Charcoal embers are not to be placed on the burner.

10.10 restricting vertical vents

Vertical installations may display a very active fl ame. If this appearance is not desirable, the vent exit must be
restricted using a restrictor vent kit. Refer to the "replacement parts" section of the owner's manual for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing down the fl ame pattern and creating a
more traditional gentle fl ame appearance. Specifi c instructions are included with the kit.

10.11 venturi adjustment

note:
An air shutter access plate has been provided for initial fl ame appearance setup. It becomes more diffi cult to
adjust once the appliance has been fi nished.
This appliance has an air shutter that has been factory set open according to the
chart below:
Regardless of venturi orientation, closing the air shutter will cause a more yellow
fl ame, but can lead to carbonization. Opening the air shutter will cause a more
blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not
appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame colour to be
established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
note:
It is important that the orifi ce is securely inserted into the venturi.
GX70-1
NG
3/8" (9.5mm)
P
Full Open
fi nishing
Venturi
Burner
Air
Shutter
Opening
W415-2371 / B / 02.05.20
EN
37