cONt-b24, bF24, b64, bF64
Contains a controller card for sequential pulsing of the valves
in the high-efficiency cleaning system. Each magnetic valve
is activated from the control cabinet. After-cleaning with the
fan turned off, "shut-down cleaning", is included as standard.
A visual alarm, which continuously monitors the condition of
the filter cartridges, is built in as standard.
ADJUSTMENTS
BUTTONS
Main functions
- MANUAL SETTING OF CLEANING INTERVAL
- AFTER-CLEANING "SHUT-DOWN CLEANING"
- AUTOMATIC SEARCH FOR CONNECTED MAGNETIC VALVES
adjustments
• Press SELECT MENU: figure 1 will flash on the display
with "+" and "-" select the PULSE TIME (0,01-9,99 sec.)
0,25 sec. factory setting.
• Press SELECT MENU: figure 2 will flash on the display
with "+" and "-" select the PAUSE TIME (1-999 sec.)
60 sec. factory setting.
• Press SELECT MENU: figure 3 will flash on the display
with "+" and "-" select the PAUSE FOR THE SHUT DOWN
CLEANING (1-999 sec.) 20 sec. factory setting.
This function requires a signal from the fan controller, see
schematics.
• Press SELECT MENU: figure 4 will flash on the display
with "+" and "-" select NO. OF CYCLES FOR SHUT DOWN
CLEANING (0-99 times) 3 times is factory setting. By
selecting the no. 000 you will bypass the SHUT DOWN
CLEANING function.
This function requires a signal from the fan controller, see
schematics.
• Press SELECT MENU: letter E will flash on the display, the
cleaning cycle will begin.
0000100513/011212/0 MDB
SELECT MENU
FUNCTIONS
PAUSE PULSE
ALARM
MENU
SELECT
RESET
VENTILATOR
LED PAUSE INDICATOR
BETWEEN 2 PULSES
LED PULSE INDICATOR
VALVE
DELTA P ALARM
HIGH PRESSURE
LOSS OVER THE
P
OK
ALARM
CARTRIDGES
MICROPROCESSOR FUNCTION
SHORT CIRCUIT ALARM
FOR OUTLETS
FAN CONTROL
ON/OFF (BF-models)
Note:
- The system will automatically ignore the outlets which have
not been connected (load search) displaying rapidly the
outlets which have not been detected.
- During the first cycle check that none of the outlets which
have been connected are ignored (in the case that they are
ignored check the connections to the valves).
23
0