3. OPERATION CONTROLS
A. On/Off Switch "I/O"
Must be in the "ON" position at all times
B. Punch Container:
Easy-to-access chip tray for quick chip disposal
C. Die Set Changes:
Are completed without tools and only take seconds to perform
D. Die Set Storage:
Holds up to 3 spare Die Sets
E. Punch Bypass:
Short straight-through paper path for unpunched documents
F. Punch Mode Path:
Wide radius turn can support stocks up to 216 g/m
Located on the front of the AdvancedPunch is a panel that provides
information relating to the operational state of the punch unit. LED
lights indicate when the AdvancedPunch requires attention from the
operator.
1. Power On:
The green LED will illuminate when the power switch on the
AdvancedPunch is set to the on position. NOTE: The power cord
for the AdvancedPunch must be plugged into the appropriate
power source prior to setting the power switch to the on position.
2. Empty Punch Container:
When the punch container becomes full of waste paper chips,
the yellow LED will illuminate.
3. Fully Insert Punch Container:
When the punch container is removed or not fully inserted into
the punch unit, the yellow LED will illuminate.
4. Close Front Door:
When the front door is open or not completely closed the yellow
LED will illuminate.
5. Clear Paper Jam:
When a sheet of paper becomes jammed within the punch unit,
the yellow LED will illuminate. See the section of this manual titled
PAPER JAMS for instructions on how to remove a sheet that has
become jammed within the AdvancedPunch.
NOTE: The LED lights on the AdvancedPunch will glow dimly
if the printer is turned on while the AdvancedPunch power
switch is in the off position. After setting the AdvancedPunch
power switch to the on position, the LED lights will illuminate
to their full intensity.
2
cover
5
AdvancedPunch
GB