Electrical Connections - FALMEC POLAR LIGHT ISOLA 35 Livret D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 38
convey the air outside of the room.
Avoid using angled pipes, make sure that the pipes are at least of the minimum length.
Comply with the current regulations on air discharge into the atmosphere.
If a boiler, stove, fireplace, etc. that uses gas or other fuels is being used at the same time,
make sure the room where the fumes are extracted is well ventilated, in compliance with the
current regulations.
Mounting instruction: see section "O" of the booklet.
D

ELECTRICAL CONNECTIONS

(Section reserved for qualified installers)
WARNING! Before doing any work inside the range hood, disconnect the appliance from the
mains power supply. Check that the wires inside the range hood are not disconnected or cut;
if this is the case, contact your nearest service centre. The electrical connections must be
performed by qualified personnel.
The connections must be performed in compliance with the legal standards in force. Check
that the relief valve and the electrical system are able to support the load of the appliance (see
the technical specifications in point B).
Some types of appliance are supplied with a cable without plug; in this case, "standardised"
plugs must be used, keeping in mind that:
- the yellow-green wire must be used for the earth,
- the blue/white wire must be used for the neutral,
- the brown/black wire must be used for the phase; the cable must not come into contact with
hot parts (over 70°C).
- fit a plug that is suitable for the load to the power cable, and connect it to a suitable power
outlet.
For appliances that come supplied with cable and plug please ensure they are plugged into a
circuit suitable for this appliance.
Please refer to a qualifed person. (See technical specifications in point B).
The manufacturer declines all liability if the safety standards are not observed.
E
RANGE HOOD WITH EXTERNAL EXHAUST
tractor hood)
In this version, the kitchen fumes and vapours are conveyed to the outside through an exhaust
pipe.
The exhaust conveyor protruding on the upper part of the hood must be connected to a pipe
carrying the fumes and vapours into an external output.
This version does not require the use of charcoal filters supplied with hoods.
When the kitchen hood is used together with other appliances using gas or other fuels, the
room must be sufficiently ventilation according to current standards.
When used in Germany:
When a range hood is simultaneously in operation with appliances supplied with energy
other than electricity, the negative pressure in the room must not exceed 4 Pa (4 x 10-5 bar).
F
RECIRCULATING HOOD
In this model, air passes through charcoal filters for purification and is then re-emitted into the
kitchen environment. For the installation of charcoal filters, please refer to section H2.
20
(filtering system)
(ex-

Publicité

Table des Matières
loading