Limited Warranty
Laerdal Medical warrants to the purchaser that its product(s)
is/are free from defects in material and workmanship for a
period of one (1) year from the date of purchase by the
original user. During the designated one (1) year period,
Laerdal Medical will, upon receipt of a product found to be
defective due to materials or workmanship from the purchaser
and notification in writing of the defect at its option repair or
replace any parts found to be defective or the entire product.
Products found to be defective and notification of defects may
also be sent to the authorized Laerdal Medical dealer from
whom the product was purchased. All postage, shipping,
or handling charges shall be the sole responsibility
of the purchaser.
Laerdal Medical is responsible for the effects of safety,
reliability and performance of its product(s) only if:
- service, repair, readjustment or modification is carried
out by Laerdal Medical or persons authorized
by Laerdal Medical.
- the product is used in the proper manner in strict
compliance with its Directions for Use.
Laerdal Medical shall not be liable under this warranty for inci-
dental or consequential damages if unauthorized repairs or
modifications have been made or attempted or when the pro-
duct, or any part thereof, has been damaged by accident, mis-
use or abuse.
This warranty does not cover batteries, fuses, normal wear and
tear, staining, discoloration or other cosmetic irregularity that
does not impede or degrade product performance.
Some states in the USA do not allow the exclusion or limitation
of incidental or consequential damages, so those limitations or
exclusions may not apply to you.
There are no other express or implied warranties, whether
of merchantability, fitness or purpose, or otherwise, on the
product, its parts and accessories.
Service
All manikin parts are replaceable. Should any part break or
wear out, it can be identified by referring to the exploded view
drawing and parts list (see page 15). Spare parts are available
from Laerdal or the local Laerdal distributor.
Since the Resusci Anne manikin is easy to disassemble and
reassemble, the manikin's owner can accomplish many repairs.
Should a problem arise, however, we will be glad to assist you.
A separate technical service manual is available.
The SkillReporter, Skillguide, MicroHeartsim and Loadbox
must be serviced by an authorized service technician.
Call your Laerdal representative for more information.
Product specifications are subject to change without notice.
Contents
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SkillReporter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Sanitation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
During class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
After class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Parts list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Standards/Approvals
The product is in compliance with essential requirements of council
directive 89 / 336 / EEC;EMC - directive.
E x p a n s i o n o f m o d e l s
The modular manikin construction allows easy expansion of
models.
To attach arms and legs:
a) Arms
Take off the manikin's jacket.
Identify right and left arm.
Be sure that the arm bolt is
mounted in the shoulder hole
of the arms. Attach the arms
by "clicking" them in place
in the holes in the torso and dress manikin. To remove,
press the arm bolt and pull the arm out of the hole
in the shoulder of the torso.
b) Lower body with legs
Attach lower body by moving
the connecting part into the
hole in the lower part of the
torso and secure it by using
the fastening bolt. To remove,
pull out the fastening bolt
and move the lower body
away from the torso.
5
Resusci Anne Modular System