© Gardner Denver Deutschland GmbH
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Zulassungen, Richtlinien und Normen
Zulassungen, Richtlinien und Normen
All wiring terminals marked to indicate proper connections for the power supply,
load and control circuitry.
The tightening, torque to connect the motor terminals, is 26.55 lb/in (size A to C)
and 5.31 lb/in to connect the PTC (in all sizes).
Instruction for operator and servicing instructions on how to mount and con-
nect the products using the intended motor connection adapter, please see
Installing the drive controller integrated in the motor and Adapter plates in the
operating manual.
Use 75° C copper wires only.
Drives do not provide over temperature sensing.
For Mx 4 used in Canada: TRANSIENT SURGE SUPPRESSION SHALL BE IN-
STALLED ON THE LINE SIDE OF THIS EQUIPMENT AND SHALL BE RATED 277
V (PHASE TO GROUND), 480 V (PHASE TO PHASE), SUITABLE FOR OVER-
VOLTAGE CATEGORY III, AND SHALL PROVIDE PROTECTION FOR A RATED
IMPULSE WITHSTAND VOLTAGE PEAK OF 2.5 kV
Maximum Surrounding Temperature (sandwich version):
Electronic
INV MA 2 0.37
INV MA 2 0.55
INV MA 2 0.75
INV MA 2 1.10
INV MA 4 0.55
INV MA 4 0.75
INV MA 4 1.10
INV MA 4 1.50
INV MB 4 2.2
INV MB 4 3.0
INV MB 4 4.0
INV MC 4 5.5
INV MC 4 7.5
INV MD 4 11.0
INV MD 4 15.0
INV MD 4 18.5
INV MD 4 22.0
CONDITIONS OF ACCEPTABILITY:
Use - For use only in complete equipment where the acceptability of the combina-
tion is determined by Underwriters Laboratories Inc.
1.
These drives are incomplete in construction and have to be attached to an
external heatsink in the end-use. Unless operated with the heatsink as noted
in item 2 of the conditions of acceptability below, temperature test shall be
conducted in the end-use.
2.
Temperature test was conducted with drive installed on aluminum heatsink,
overall dimensions and ribs shape as outlined below:
3.
Suitability of grounding for the combination of drive and heatsink needs to be
verified in accordance with the end-use standard.
Overall heatsink dimen-
sions
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(150x27x210) mm
(200x40x250) mm
(200x40x250) mm
(200x40x250) mm
(216x83x300) mm
(216x83x300) mm
to be defined
to be defined
to be defined
to be defined
29
/
34
Tel. 071 918 60 60, Mail: v-g@prematic.ch
5
Surroundin
Suffix
g
50° C
Gx3
50° C
Gx3
50° C
Gx3
50° C
Gx3
65° C
Gx3
65° C
Gx3
65° C
Gx3
65° C
Gx3
60° C
Gx3
60° C
Gx3
60° C
Gx3
65° C
Gx3
65° C
Gx3
to be
Gx3
defined
to be
Gx3
defined
to be
Gx3
defined
to be
Gx3
defined
07.2014 · 610.00260.01.010