Description

The DC 3500 TR is a machine with large suction
capacity and robust construction while still being
compact and easy to maneuver.
It is ideal for spot extraction on most types of hand-
held tools and for industrial cleaning
(38 mm and 50 mm system).
The extraction system functions with negative
pressure (vacuum) that draws the air through suction
casings/nozzles, hose system, separator and filter
system. Coarse separation of dust occurs in the units
cyclone which is a highly efficient separator for larger

Operation

The filter should be cleaned 1-2 times per day with
continuous running or if the machine is equipped with
a filter monitor, when this is in the red area.
For filter cleaning:
1. Start the machine.
2. Disconnect the hose from the suction casing.
3. Place the suction hoses free end over the filter
cleaning handle.
4. With slow, even motion open the pulse top by
depressing the handle. Repeat three to
four times.
5. Reconnect the hose to the suction casing.
particulate. The fine dust is separated and contained
by the units filter system. Separated material is
collected for disposal in the plastic sack or container
at the base of the cyclone.
The vacuum is generated in an ejector which means:
- maintenance free vacuum producer
- low weight
- no electrical connection required in hazardous
environments
- extremely reliable
The filter is cleaned with reverse pulse giving the fil-
ter extra long life and retaining maximum capacity.
6. If the filter condition meter reads green work
can continue, if in the red, pulse clean again.
If after several repetitions, the filter condition
still shows red the fine filter 408801 must be
changed.
The plastic sack should be changed only after the filter
has been cleaned. The sack should be changed when
the dust level is about 5 cm under the foot valve. The
plastic sack should be sealed after
removal from the machine.
Use only original plastic sacks.
Note! Low main pressure and damages in the
compressed-air line will result in poor
performance.