WARNING
Technical Data
Mains voltage / Frequency
Absorbed power
Type of protection / Insulation class
Suction fitting
Delivery fitting
Maximum flow rate*
Maximum head*
Maximum suction height including load losses
Power cable
Weight
Maximum dimension of pumped solid particles 3 mm
Maximum admitted working pressure
Minimum ambient temperature
Maximum ambient temperature
Maximum temperature of the pumped fluid
in continuous mode
Maximum number of starts per hour,
uniformly distributed
Technical Data
Mains voltage / Frequency
Absorbed power
Type of protection / Insulation class
Suction fitting
Delivery fitting
Maximum flow rate*
Maximum head*
Maximum suction height including load losses
Power cable
Weight
Maximum dimension of pumped solid particles
Maximum admitted working pressure
Minimum ambient temperature
Maximum ambient temperature
Maximum temperature of the pumped fluid in continuous mode
Maximum number of starts per hour, uniformly distributed
(*) The specifications above are referred to a configuration with a free and unreduced delivery mouth.
Ch. 3 Installation (see Fig. 1)
DANGER
Electric shock
risk
WARNING
DANGER
Use a suction pump (2) with a diameter equivalent to that of the suction mouth of the electropump (1).
If the height (HA) is over 4 meters use a tube with a larger diameter. The suction line should be perfectly airtight. No
elbows and/or slopes should be present to prevent the formation of air locks that could affect the electropump
efficiency. A foot valve (3) with filter (4) should be fitted at about half a metre below the fluid that has to be pumped
(HI) on one end of the line. Load losses can be reduced using delivery piping with a diameter equivalent or greater than
the electropump mouth (5). It is advisable to install a check valve (6) directly on the delivery line to prevent the
electropump being damaged by "water hammer".
6
The pump cannot be used for sea water and inflammable, corrosive, explosive or
dangerous liquids.
GARDENJET 1000
230 V ~ 50 Hz
1100 Watt
IP 44 / F
1"
1"
4.200 l/h
50 m
7 m
1,5 m H07 RNF
17,4 Kg
6 bar
5° C
40° C
50° C
40
When installing, please ensure electropump is disconnected from
electrical supply.
Protect the electropump and all pipes from bad weather or freezing conditions.
To prevent possible injuries to people, avoid inserting hands into the mouth of the
pump if this is connected to the mains.
GARDENJET
INOX 1000
230 V ~ 50 Hz
800 Watt
IP 44 / F
1"
1"
3.600 l/h
46 m
7 m
1,5 m H07 RNF
9,2 Kg
3 mm
6 bar
5° C
40° C
50° C
40
PURADOM
230 V ~ 50 Hz
650 Watt
IP 44 / F
1"
1"
3.600 l/h
42 m
7 m
1,5 m H07 RNF
7 Kg
3 mm
5 bar
5° C
40° C
50° C
40
2
GB
GARDENJET
INOX 1500
230 V ~ 50 Hz
1100 Watt
IP 44 / F
1"
1"
4.000 l/h
50 m
7 m
1,5 m H07 RNF
9,2 Kg
3 mm
6 bar
5° C
40° C
50° C
40
GARDY
230 V ~ 50 Hz
800 Watt
IP 44 / F
1"
1"
3.600 l/h
46 m
7 m
1,5 m H07 RNF
8,8 Kg
3 mm
5 bar
5° C
40° C
50° C
40