3 41 01 117 21 0.book Seite 10 Dienstag, 13. September 2011 8:13 08
en
10
Emission values for sound and vibration (Two-figure – specifications as per ISO 4871)
Sound emission
A-weighted emission pressure power
level measured at the workplace L
(re 20 µPa), in decibels
Measuring uncertainty K
pA
Measured A-weighted sound power level
L
(re 1 pW), in decibels
wA
Measuring uncertainty K
wA
C-weighted peak sound pressure level
measured at the workplace L
decibels
Measuring uncertainty K
pCpeak
Vibrations
Mean vibrational value for angle grinding
, in
h,AG
2
m/s
2
ft/s
Mean vibrational value for sanding with
sanding sheet
h,DS
, in
2
m/s
2
ft/s
Measuring uncertainty K, in
2
m/s
2
ft/s
REMARK: The sum of the measured emission value and respective measuring inaccuracy represents
the upper limit of the values that can occur during measuring.
Wear ear protection!
Measured values determined in accordance with the corresponding product standard.
WSG10-115 WSG10-125S
pA
, in decibels
, in decibels
, in
pCpeak
, in decibels
WSG14-125 WSG14-125S
84
84
3
3
95
95
3
3
99
99
3
3
5.0
4.5
15
13.5
2.5
2.5
7.5
7.5
1.5
1.5
4.5
4.5
87
84
3
3
98
95
3
3
99
99
3
3
5.0
4.5
15
13.5
2.5
2.5
7.5
7.5
1.5
1.5
4.5
4.5